Installation Manual

Maintenance 9-15
7. Visually inspect the cleaned cables for uneven and excessive wear. Run a lint-free cloth over
cables while feeling for breaks in sheathing or swollen spots.
? NOTE If the cables show signs of wear, skip this procedure and contact Asymtek. If the
cables show no signs of wear, proceed with the next step.
8. Manually move the Dispensing Head to the rear middle of the dispensing area and repeat
Steps 6 and 7.
9. Wearing rubber gloves, manually apply an adequate but not excessive amount of grease to
the exposed portion of all mechanical cables.
10. Manually move the carriage to the front middle of the system and repeat Step 9.
Item Description
1 Side Panels
2 Safety Covers
3 Servo Shelf Cover
4 Electrical Cable Cover
5 Motor Cover
6 Motor Pulley Access Panel
7 Mechanical Cables
Figure 9-7 Accessing the Positioner Cables
2
3
4
7
1
56