Installation Manual
Emergency Shutdown
Your Axiom X-1000 Series Dispensing System features EMO buttons that the operator or service
technician can use to immediately stop all dispensing operations in case of emergency. This feature helps
prevent injury to personnel and damage to the dispensing system and workpieces being processed.
Your dispensing system design includes two EMO buttons. One EMO button is located on the Operator’s
Console, and the second is located on the rear panel of the dispensing system (see
Figure 2-6). The
EMO vents all pressure in the pneumatic system, de-energizes the servo power supply capacitors, and
cuts power to all system components except the Computer and Monitor. Refer to Appendix B for the EMO
circuit diagram.
" NOTE If the operator or technician is unable to reach the EMO button, the Main Circuit Breaker
can be used for emergency shutdown, but doing this may cause irreparable damage to the
Computer and software.
1
2
Item Description
1 Front EMO Button
2 Rear EMO Button
Figure 2-6 EMO Locations
Safety 2-13