Installation Manual

Maintenance 9-11
5. Repeat Step 4 for the X-axis and then the Y-idle Cable Tensioners.
6. From the mid-Y and mid-X position, manually move the Dispensing Head as follows for two
complete cycles as follows:
a. to the left rear corner of the dispensing area
b. to the right rear corner
c. to the right front corner
d. to the left front corner
7. When the second cycle is complete, manually move the Dispensing Head to the mid-Y and
mid-X position.
8. Repeat Steps 4 through 7.
9. Perform a Post-Service Start-up as specified in the Safety section of this manual.
Item Description
1 Cable Tensioner
2 Calibrated Tensioning Tool (P/N 48-8002)
3 Positioner Cable
Figure 9-5 Tensioning the Positioner Cables
3
2
1