Installation Manual

9-8 Maintenance
Draining the Water Trap
The facility air supply may contain moisture that can damage the dispensing system. The water trap
condenses this moisture before it enters the dispenser pneumatic system. The operator or technician
should drain the water trap weekly or whenever it is full.
WARNING! Do not remove the bowl guard protecting the water trap. The bowl is made of
polycarbonate plastic, which could rupture from over-pressurization or if the bowl
has been exposed to chemicals incompatible with polycarbonate. Removing the
bowl guard can result in serious bodily harm to the user.
Tools and Materials Needed
Container for waste water
To empty the water trap:
1. Perform a Service Shutdown as specified in the Safety section of this manual.
2. Locate the water trap at the rear of the system (see Figure 9-3).
3. Hold a container under the water trap to catch the water.
4. Open the water drain knob by turning counterclockwise.
WARNING! Make sure that all air pressure to the system has been removed before opening
the drain or serious injury may occur.
5. After the trap has been drained, close the water trap drain knob by turning it clockwise.
6. Perform a Post-Service Start-up as specified in the Safety section of this manual.