Installation Manual

9-6 Maintenance
To replace the Purge and Weigh Station cups:
? NOTE The Valve Offsets routine does not need to be performed after replacing the Purge Station
and Weigh Station cups.
1. If a dispensing program is running, click on
Pause in the FmNT Run Window.
> The dispensing system will complete the current workpiece and then pause.
2. With no dispense program running, open the dispensing system Hatch.
3. Remove the Purge and Weigh Station covers. See Figure 9-2.
WARNING! Follow all manufacturer MSDS, facility requirements, and local ordinances
concerning personal protective equipment and disposal of hazardous materials.
4. Remove and discard the plastic cup inside the Purge Station and inspect the interior surfaces
for spilled fluid.
> If the interior of the Purge Station has spilled fluid, clean with the fluid manufacturer
MSDS recommended solvent and a soft cloth.
5. Remove and discard the cup and banjo wiper inside the Weigh Station and inspect the interior
surfaces for spilled fluid.
> If the interior of the Weigh Station has spilled fluid, call a service technician.
CAUTION! Avoid putting pressure on the Scale Pedestal or damage to the sensitive
weighing mechanism will occur.
6. Place a new plastic cup inside of each station.
7. Place a new banjo wiper into the Weigh Station cup such that the wide sides of the wiper are
perpendicular to the Conveyor Rail.
8. Clean the covers using isopropyl alcohol and a soft cloth.
9. Replace the Purge Station and Weigh Station Covers.