Installation Manual

Troubleshooting 8-147
17. Click on the Settings tab and then select ASCII Setup.
18. Select the
Echo typed characters locally checkbox.
19. Click
OK and then OK again.
20. Type [P] then press [Enter] and observe if the Scale responds with a numeric value.
21. Did the Scale respond with a value?
Go to Step 22
Computer (P/N 194751) has failed. See
Parts Replacement section.
22. Close the HyperTerminal and exit Windows NT.
23. Press the black
OFF (0) button on the Operator’s Console, switch Main Circuit Breaker to OFF (0)
position, and disconnect Power Cable from the facility outlet.
24. Check the Scale Communications Cable (P/N 06-4582-00) for continuity as specified in Table 8-45.
Table 8-45 Scale Communications Cable Pinout
P1 P2
31
52
43
64
26
25. Is there continuity?
Scale Communications Cable (P/N 06-4582-00)
has failed. See
Parts Replacement section.
Scale (P/N 62-1614-00) has failed. See
Parts Replacement section. (Balance
and Control Modules must be a matched set by serial number.)
No
Yes
No
Yes