8-140 Troubleshooting
Mechanical Verification
1. Inspect and confirm that the following conditions are present:
a. System installation properly leveled and footpads firmly seated on floor.
b. No noticeable vibrations in the dispensing system or adjacent machinery.
c. No loose, damaged, or pinched cables.
d. Scale Balance properly installed and leveled.
e. Scale Cup Cover properly in place.
f. Scale Pedestal not damaged and has no residual fluid build-up.
g. Scale has a valid date on the calibration label.
h. Scale Control Module and the Balance Module have matching serial numbers.
2. Is any mechanical correction required as a result of Step 1 inspections?
Go to Scale Operational Verification in
this subsection.
Resolve and go to Scale Operational Verification in this subsection.
Scale Operational Verification
1. Connect the Power Cable to the facility outlet, switch Main Circuit Breaker to
ON (I) position, press
the green
ON (I) button on the Operator’s Console, and enter FmNT.
2. Did the Scale initialize?
Go to Step 3
Go to Step 5
3. Locate and observe the green LED on the Scale Control Module.
4. Is the green LED illuminated?
Go to Scale Power Verification in this subsection.
Go to Scale Communications Verification in this subsection.
5. In the FmNT Main Window, click on the Configuration and select Setup Scale.
? NOTE Scale requires a one-hour warm up period after prolonged dispensing system
power down
.
No
Yes
No
Yes
No
Yes