Installation Manual
8-134 Troubleshooting
8.5.2 Tactile Sensor or Needle Sensor Fault Isolation Procedure
The Tactile Sensor and Needle Sensor Fault Isolation Procedure consists of the following:
• Dispensing Calibration Module Verification
• Tactile Sensor Verification
• Needle Sensor Verification
Before troubleshooting a problem, please familiarize yourself with the important information provided in
the Safety section of this manual.
WARNING! A dispensing system in need of component troubleshooting may have high
voltage present in both designated and unsuspected places that can result in
personal injury or death. Follow safety precautions listed in the Safety section of
this manual.
WARNING! Disconnect and lock out power to adjacent systems connected to the dispensing
system (such as loaders and ovens) before troubleshooting. Failure to do so may
result in serious personal injury or death.
CAUTION! Troubleshooting should only be performed by an Asymtek Field Service Engineer
or an Asymtek-trained service technician.
Dispensing Calibration Module Verification
1. Switch Main Circuit Breaker to
ON (I) position, press the green ON (I) button on the Operator’s
Console, and enter FmNT.
2. Locate the power LEDs on the Main Interface PWA.
3. Are the green
+5V, +12V, -12V, and A+5V LEDs illuminated?
Go to 8.1.3, System Power Fault Isolation
Procedure
Go to Tactile Sensor Verification or Needle Sensor Verification in this
subsection, as appropriate
No
Yes