9. Click on the Start button in the lower middle window.
10. Was the Height Sense test within the ranges shown in Table 8-40?
Go to Step 15
Go to Step 11
11. In FmNT, increase the cycle number setting to 100.
12. Click on the
Start button in the lower middle window.
13. When Height Sense test is complete, compare the results with the accuracy parameters specified in
Table 8-40.
14. Was the result within the accuracy parameters specified in Table 8-40?
Go to Step 15
Stop here. Height Sensor meets accuracy parameters. Verify fault. If fault
reoccurs, contact Asymtek Technical Support.
15. Verify that the Height Sensor, Height Sensor Probe, and the Micrometer Locking Screw are installed
correctly and securely.
16. Any adjustments required?
Go to Step 17
Make adjustments and then go to Step 18.
17. Repeat Steps 1 through 13.
18. Was the test result within the accuracy parameters specified in Table 8-40?
Contact Asymtek Technical Support
Stop here. Mechanical adjustment is root cause of Height Sensor fault.
No
Yes
No
Yes
No
Yes
No
Yes