Installation Manual
8-128 Troubleshooting
Height Sensor Probe Verification
1. Open FmNT and in the Main Window click on
Configuration.
2. In the drop-down menu, select Setup Height Sensor.
3. In the Height Sensor Configuration Window, click on the CAN-HS button.
4. Click on
CAN-HS button in the upper right-hand corner of the window until Main Menu appears.
5. Click on
Arm /Disarm button and observe if the Height Sensor Probe moves up and down.
6. Does the Height Sensor Probe move up for Disarmed state and down for the Armed state?
Go to Height Sensor CAN Interface Verification
in this subsection.
Go to Step 7
WARNING! CAUTION!
Use caution when reaching your hand into the dispensing area while system is
under power. Failure to take appropriate precautions could result in personal
injury or property damage.
7. With the Height Sensor in the Armed state, use your hand to move the Height Sensor Probe upward
then hold it in that position while observing the Current State.
8. Does the Current State change to ON?
Go to Height Sensor CAN Interface Verification
in this subsection.
Go to Step 9
9. Click on OK.
10. In the FmNT Main Window, click on
Tools.
11. In the Tools Window, click on
I/O Test and then click on the Dispenser button.
12. In the I/O Test Dialog Window, click on the
PIO 96 Channels 10-13 tab.
13. Under the Channel 11 section of the window, find the HS_TOUCH/ [4A0] signal.
No
Yes
No
Yes