Installation Manual
Troubleshooting 8-123
9. Disconnect the Rear Belt Motor connector from the Conveyor Interconnect PWA.
10. Install the Width Motor connector into the Rear Belt Motor receptacle.
11. Connect the Power Cable to the facility outlet, switch Main Circuit Breaker to
ON (I) position, press
the green
ON (I) button on the Operator’s Console, and enter FmNT.
12. From any FmNT Window, click on the
Jog icon, or press [Ctrl + J] on the Keyboard.
13. Click on
Conveyor and use the Jog Controls to move the Conveyor Belts.
14. Did the Width Motor turn?
Go to Step 18
Go to Step 15
15. Exit FmNT, shut down Windows NT, press the black OFF (0) button on the Operator’s Console,
switch Main Circuit Breaker to
OFF (0) position, and disconnect Power Cable from the facility outlet.
16. Check continuity (Pinout is 1 to 1) of Stepper Motor Cable (Conveyor Controller to the Conveyor
Interconnect PWA).
17. Is there continuity?
Stepper Motors Cable (P/N 06-4612-00) has failed.
See
Parts Replacement section.
Conveyor Controller (P/N 62-1677-00 on X-1020, or P/N 62-1676 on X-1010)
has failed. See Parts Replacement section.
18. Check continuity (Pinout is 1 to 1) of Width Motor Cable (Interconnect PWA to Motors).
19. Is there continuity?
Width Motor Cable (P/N 06-4624-00) has failed.
See
Parts Replacement section.
Width Motor (P/N 07-0716-00) has failed. See
Parts Replacement section.
No
Yes
No
Yes
No
Yes