Installation Manual
Troubleshooting 8-115
19. Verify continuity of the P/N 06-4645-00 SMEMA Upstream Cable, routed between Conveyor
Controller and the Rear Bulkhead of the dispensing system. Pin connections are specified in
Table 8-34.
Table 8-34 SMEMA Upstream Cable Pin Connections
P1 Color P2
1Black 9
2White 3
3 Red 10
4 Green 4
5Brown 1
6Blue 2
7 Orange 11
8Yellow12
9PurpleN/C
Shell Shield 8
20. Is there continuity?
SMEMA Upstream Cable (P/N 06-4645-00) has
failed. See
Parts Replacement section.
Conveyor Controller (P/N 62-1677-00 on X-1020, or P/N 62-1676 on X-1010)
has failed. See Parts Replacement section.
21. If applicable, reinstall the Conveyor Controller Cover.
No
Yes