Installation Manual

Troubleshooting 8-107
25. When the Board Sensor is unblocked, is the reading 24 VDC?
Conveyor Controller (P/N 62-1677-00 on X-1020 or
P/N 62-1676 on X-1010) has failed. See
Parts
Replacement
section.
Go to Step 26
26. When the Board Sensor is blocked, does the Conveyor Controller toggle from High (24 VDC) to
Low (approximately 0 VDC)? (Note: Low is activated.)
Go to Conveyor Signals Cable Verification in
this subsection.
Conveyor Controller (P/N 62-1677-00 for X-1020 or 62-1676-00 for X-1010)
has failed. See
Parts Replacement section.
27. Reinstall the Dispensing Area Front Cover.
Conveyor Signals Cable Verification
1. Exit FmNT, shut down Windows NT, press the black
OFF (0) button on the Operator’s Console,
switch Main Circuit Breaker to
OFF (0) position, and disconnect Power Cable from the facility outlet.
2. Check continuity of Conveyor Signals Cable (Pinout is 1 to 1).
3. Is there continuity?
Conveyor Signals Cable (P/N 06-4610-00) has
failed. See
Parts Replacement section.
Conveyor Controller (P/N 62-1677-00 for X-1020 or 62-1676-00 for X-1010)
has failed. See
Parts Replacement section.
No
Yes
No
Yes
No
Yes