Troubleshooting 8-105
8. Does the Board Sensor status indicator LED illuminate when a workpiece is passed beneath it?
Go to Step 9
Go to Step 14
9. Inspect the Fiber-optic Cables for any damage that will interfere with light transmission.
10. Is the Fiber-optic Cable damaged?
Go to Step 11
Fiber-optic Cable (P/N 56-0124) has failed. See
Parts Replacement section.
11. Attach the Fiber-optic Cable from the failed Board Sensor to one of the other Board Sensors.
12. Did the error follow the exchanged Fiber-optic Cable?
Go to Step 13
The Fiber-optic Cable (P/N 56-0124) has failed. See
Parts
Replacement
section.
13. Did the error stay with the Board Sensor Amplifier?
Stop here. The Fiber-optic Cable is not root cause
of the fault. Install Fiber-optic Cables to their
original locations.
Go to Step 14
14. In FmNT, observe the Conveyor I/O screen display on the Monitor.
15. Is the bit changing in the Conveyor I/O screen display when a workpiece is passed beneath it?
Go to Step 16
Stop here. The Board Sensor is not root cause of the fault.
16. Exit FmNT, shut down Windows NT, press the black OFF (0) button on the Operator’s Console,
switch Main Circuit Breaker to
OFF (0) position, and disconnect Power Cable from the facility outlet.
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes