8-104 Troubleshooting
Facility Power Supply Verification
1. Is facility power in accordance with the requirements in the Introduction section of this manual?
Resolve and go to Board Sensor Verification in
this subsection.
Go to Board Sensor Verification in this subsection.
Board Sensor Verification
1. Exit FmNT, shut down Windows NT, press the black
OFF (0) button on the Operator’s Console,
switch Main Circuit Breaker to
OFF (0) position, and disconnect Power Cable from the facility outlet.
WARNING! CAUTION!
Use caution when reaching your hand into the dispensing area while system is
under power. Failure to take appropriate precautions could result in personal
injury or property damage.
2. Manually move the Dispensing Head to the rear of the dispensing area and then remove the
Dispensing Area Front Cover.
3. Connect the Power Cable to the facility outlet, switch Main Circuit Breaker to
ON (I) position, press
the green
ON (I) button on the Operator’s Console, and enter FmNT.
4. Does the Board Sensor status LED illuminate when a workpiece is passed by it?
Go to Step 5
Go to Step 14
5. Check the Board Sensor for proper position and beam direction.
6. Is the Board Sensor beam hitting upper portion of the Conveyor Rails or going through the
Carrier holes?
Go to Step 7
Adjust the Board Sensor position and then go to Step 7.
7. Adjust the Board Sensor sensitivity. Refer to Calibration and Adjustment section in this manual.
No
Yes
No
Yes
No
Yes