8.4.2Board Sensor Fault Isolation Procedure
The Board Sensor Fault Isolation Procedure consists of the following:
Mechanical Verification
Facility Power and Air Supply Verification
Board Sensor Verification
Conveyor Signals Cable Verification
Before troubleshooting a problem, please familiarize yourself with the important information provided in
the Safety section of this manual.
WARNING! A dispensing system in need of troubleshooting may have high voltage present in
both designated and unsuspected places that can result in personal injury or
death. Follow safety precautions listed in the Safety section of this manual.
WARNING! Disconnect and lock out power to adjacent systems connected to the dispensing
system (such as loaders and ovens) before troubleshooting. Failure to do so may
result in serious personal injury or death.
CAUTION! Troubleshooting should only be performed by an Asymtek Field Service Engineer
or an Asymtek-trained service technician.
Mechanical Verification
1. Perform the following inspections:
a. Look for nicked, cut, or pinched Fiber-optic Cables.
b. Look for disconnected or poorly secured Fiber-optic Cables to the Sensor Amplifier.
c. Look for disconnected or poorly secured electrical cables.
d. Look for damaged electrical cables.
e. Look for loose sensor mounting hardware.
2. Is any mechanical correction required as a result of Step 1 inspections?
Go to Facility Power and Air Supply Verification
in this subsection.
Resolve and go to Facility Power and Air Supply Verification in
this subsection.
No
Yes