Installation Manual
8-100 Troubleshooting
18. Check continuity of Servo Interconnect B Cable (Pinout is 1 to 1).
19. Is there continuity?
Servo Interconnect B Cable (P/N 06-4525-00) has
failed. See
Parts Replacement section.
Go to Step 20
20. Exchange failed Solenoid Valve with one of the other Solenoid Valves (refer to Parts Replacement
section for removal and installation of the Solenoid Valve).
21. Connect the Power Cable to the facility outlet, switch Main Circuit Breaker to
ON (I) position, press
the green
ON (I) button, and enter FmNT.
22. Toggle the Solenoid Valves listed in Table 8-29, as applicable.
23. From the FmNT Main Window:
a. Select
Tools.
b. Select
I/O Test.
c. Select
Conveyor.
24. Did the failure follow the exchanged Solenoid Valve (Step 20 above)?
Go to Step 25
Solenoid Valve has failed. See
Parts Replacement section.
25. Exit FmNT, shut down Windows NT, press the black OFF (0) button on the Operator’s Console,
switch Main Circuit Breaker to
OFF (0) position, and disconnect Power Cable from the facility outlet.
26. Disconnect Conveyor Signals Cable P3 from Conveyor Controller.
27. Connect the Power Cable to the facility outlet, switch Main Circuit Breaker to
ON (I) position, press
the green
ON (I) button on the Operator’s Console, and enter FmNT.
28. From the FmNT Main Window:
a. Select
Tools.
b. Select
I/O Test.
c. Select
Conveyor.
29. Toggle the failed pneumatic device. Refer to Table 8-29 for location.
No
Yes
No
Yes