Installation Manual

8-98 Troubleshooting
Pneumatics Verification
1. Connect the Power Cable to the facility outlet, switch Main Circuit Breaker to
ON (I) position, press
the green
ON (I) button on the Operator’s Console, and enter FmNT.
2. Are all pneumatic system devices inoperative and the yellow Beacon light flashing?
Go to Step 3
Go to Step 7
3. From the FmNT Main Window:
a. Select
Tools.
b. Select
I/O Test.
c. Select
Conveyor.
4. Toggle the failed pneumatic device. Refer to Table 8-29 for applicable Solenoid Valve as seen from
the front of the dispensing system.
Table 8-29 Pneumatic Solenoids
X-1010
5 4 3 2 1A
Center Lift
Center Stop Pin
Left Stop Pin
Purge cup
X-1020
8 7 6 5 4 3 2B 2A 1B 1A
Right Lift Table
Left Lift Table
Right Stop Pin
Center Lift Table
Center Stop Pin
Left Stop Pin
Right Vacuum
Left Vacuum
Center Vacuum
Purge cup
5. Did the LED illuminate on the Solenoid Valve?
Go to Step 20
Go to Step 6
No
Yes
No
Yes