Installation Manual
Troubleshooting 8-97
Mechanical Verification
1. Perform the following inspections:
a. Listen for pneumatic leaks (a hissing sound).
b. Look for cuts or disconnected pneumatic hoses.
c. Look for pinched or obstructed pneumatic hoses.
d. Look for obstructions that prevent Lift Tables and Stop Pins to raise or lower.
e. Look for disconnected or poorly secured electrical cables.
f. Look for damaged electrical cables.
2. Is any mechanical correction required as a result of Step 1 inspections?
Go to Facility Power and Air Supply Verification
in this subsection.
Resolve and go to Facility Power and Air Supply Verification in
this subsection.
Facility Power and Air Supply Verification
1. Is facility power and air supply in accordance with the requirements in the Introduction section of
this manual?
Resolve and then go to Step 2.
Go to Step 2
2. Are power and air supply lines properly connected to the dispensing system and is the Main Pressure
Regulator set to 80 psi?
Resolve and then go to Pneumatics Verification in
this subsection.
Go to Pneumatics Verification in this subsection.
No
Yes
No
Yes
No
Yes