Installation Manual
Troubleshooting 8-87
8.3.2Z Servo Amplifier Fault Isolation Procedure
The Z Servo Amplifier Fault Isolation Procedure consists of the following:
• Main Power Verification
• Servo Power Verification
• Servo Amplifier Verification
• External Disable Check
• Power-up Reset Check
Before troubleshooting a problem, please familiarize yourself with the important information provided in
the Safety section of this manual.
WARNING! A dispensing system in need of troubleshooting may have high voltage present in
both designated and unsuspected places that can result in personal injury or
death. Follow safety precautions listed in the Safety section of this manual.
WARNING! Disconnect and lock out power to adjacent systems connected to the dispensing
system (such as loaders and ovens) before troubleshooting. Failure to do so may
result in serious personal injury or death.
CAUTION! Troubleshooting should only be performed by an Asymtek Field Service Engineer
or an Asymtek-trained service technician.
Main Power Verification
1. Verify that the Main Circuit Breaker located on the Power Manager is in the
ON (I) position.
2. Is the Power Manager Fan functioning?
Go to 8.1.2, Main Power Fault Isolation
Procedure
Go to Step 3
3. Is the green Computer power LED illuminated?
Go to Step 4
Go to Step 6
No
Yes
No
Yes