Installation Manual
8-72 Troubleshooting
2. Is any mechanical correction required as a result of Step 1 inspections?
Go to 8.2.3, PMAC Linear Encoder Fault
Isolation Procedure
Go to Step 3
3. Press the black OFF (0) button on the Operator’s Console.
4. Open the Front Hatch and manually move the Dispensing Head throughout the dispensing chamber in
the X or Y, and Z-axis.
5. Are movements smooth and linear with no binding or unusual noise?
Go to Servo Motor Verification in this subsection.
Go to Step 6
6. Press the green ON (I) button on the Operator’s Console and open FmNT.
7. Does Dispensing Head complete the homing process with no FmNT messages.
Go to 8.2.1, PMAC Initialization Fault Isolation
Procedure
Go to Step 8
8. Can the Dispensing Head be moved in X and Y axes with the Jog keys [Ctrl + Shift + Arrow keys] on
the Keyboard?
Go to “PMAC Fatal Following Error Verification”
in 8.2.1, PMAC Initialization Fault
Isolation Procedure
Go to Step 9
9. From the FmNT Main Menu, click on the Jog icon.
10. In the Jog Window, point and click at several locations in the blue square to move the Dispensing
Head throughout the dispensing chamber.
No
Yes
No
Yes
No
Yes
No
Yes