Installation Manual

Troubleshooting 8-65
X-Axis Linear Encoder Verification
1. From the FmNT Main Menu, click on the
Tool icon.
2. In the Tool Menu, click on the
Terminal icon.
3. Under the Terminal icon, click on the
Dispenser icon.
4. Press the black
OFF (0) button on the Operator’s Console.
5. In the Dispenser Terminal window, type M201 and press [Enter] on the Keyboard. A numerical value
should appear. Note the value returned.
WARNING! CAUTION!
Use caution when reaching your hand into the dispensing chamber while system
is under power. Failure to take appropriate precautions could result in injury or
property damage.
6. Manually move the Dispensing Head in the X-axis.
7. Again, type M201 and press [Enter]. Note the value returned.
8. Are the two numerical values from Step 5 and Step 7different?
Go to Step 17
Go to Step 9
9. Manually move the Dispensing Head to the mechanical hard stops in the front left corner of the
dispensing chamber.
10. Type M201 and press [Enter] on the Keyboard. Note the value returned.
11. Manually move the Dispensing Head in random directions at different speeds trying to cover the
entire dispensing chamber.
12. Return the Dispensing Head to the mechanical hard stops in the front left corner of the dispensing
chamber.
13. Again, type M201 and press [Enter]. Note the value returned.
14. Record the difference between the numeric values noted in Step 10 and Step 13.
15. Repeat Steps 9 through 14 three times.
No
Yes