Installation Manual
8-62 Troubleshooting
17. Is the difference of any set of values greater than 200 counts?
Z-axis Rotary Encoder is not root cause of the
following error fault. Go to Step 9 in “PMAC Fatal
Following Error Verification” in 8.2.1, PMAC
Initialization Fault Isolation Procedure.
Stop here. Rotary Encoder is root cause of following error fault. Contact
Asymtek Technical Support to verify fault.
18. Remove the Servo Shelf Cover.
19. Check continuity of Z-Head Interconnect Cable (P/N 06-4550-00.) Pinout is 1 to 1.
20. Does the Z-Head Interconnect Cable have continuity?
Z-Head Interconnect Cable (P/N 06-4550-00) has
failed. See
Parts Replacement section.
Go to Step 21
21. Check continuity of signal routing from the Z-axis Rotary Encoder as specified in Table 8-21.
Table 8-21 Z-axis Rotary Signal Routing
Signal
From (PWA)
Via
To (PWA)
A Pin 4 at J31 (XY Servo Interface) XY Servo Interface PWA Pin 11 at J19 (XY Servo Interface)
B Pin 5 at J31 (XY Servo Interface) XY Servo Interface PWA Pin 10 at J19 (XY Servo Interface)
A Pin 11 at J19 (XY Servo Interface) Cable (P/N 06-4525-00) Pin 11 at J29 (Main Interface)
B Pin 10 at J19 (XY Servo Interface) Cable (P/N 06-4525-00) Pin 10 at J29 (Main Interface)
A Pin 11 at J29 (Main Interface) Main Interface PWA Pin 11 at J11 (Main Interface)
B Pin 10 at J29 (Main Interface) Main Interface PWA Pin 10 at J11 (Main Interface)
A Pin 21 at J11 (Main Interface) Cable (193320) Pin 21 at J7 PMAC Controller
B Pin 25 at J11 (Main Interface) Cable (193320) Pin 25 at J7 PMAC Controller
22. Is there continuity of signal routing for the Z-axis Rotary Encoder?
The isolated part has failed. See Parts
Replacement
section.
Rotary Encoder (P/N 62-1664-00) has failed. See
Parts
Replacement
section.
No
Yes