Installation Manual
8-54 Troubleshooting
14. Locate the Computer Passive Backplane on the right inside wall of the Computer. Locate four red
LEDs labeled -5V, +5V, -12V, and +12V.
15. Are all the LEDs illuminated?
Go to 8.1.2, Main Power Fault Isolation
Procedure
PMAC Card (P/N 07-0735-01) has failed. See
Parts Replacement section.
PMAC Fatal Following Error Verification
1. Reinitialize the Dispenser.
2. FmNT message “30416 Dispenser motor reference not found. Select OK to home the dispenser”
should appear.
3. Do not home the Dispensing Head.
4. Use the Jog keys [Crtl + Shift + Arrow Keys] on the Keyboard to move the Dispensing Head in one
axis.
CAUTION! When Dispensing Head travel limits are not correct, the Dispensing Head can hit
hard stops causing potential hardware damage.
5. Observe the movement of each axis to isolate the cause of Fatal Following Error.
6. Was there high vibration during the X or Y-axis movement?
Go to Step 7
Go to 8.2.2, PMAC Rotary Encoder Fault Isolation Procedure
7. Was there a fast movement in the X or Y-axis with no vibration before the Dispensing Head came
to a stop?
Go to Step 8
Go to 8.2.3, PMAC Linear Encoder Fault Isolation Procedure
No
Yes
No
Yes
No
Yes