Installation Manual
Troubleshooting 8-47
10. Can the Dispensing Head be moved in X and Y axes with the Jog keys [Ctrl + Shift + Arrow keys] on
the Keyboard?
Go to Step 11
Stop here. Dispensing Head initialization is root cause of Servo
Amplifier fault.
11. Does the green Beacon light illuminate when the Front Hatch is closed?
Go to “Light Beacon Signal Verification” in 8.1.4,
Interlock Fault Isolation Procedure
Go to Step 12
12. Is the red SRVO_PWR LOW LED on the XY Servo Interface PWA not illuminated when the Front
Hatch is closed?
Go to 8.1.4, Interlock Fault Isolation Procedure
Go to Step 13
13. Does a Door open message appear in the bottom left corner of the FmNT window when the Front
Hatch is closed?
Go to 8.2, Troubleshooting the Servo Controller
Go to 8.1.4, Interlock Fault isolation Procedure
No
Yes
No
Yes
No
Yes
No
Yes