8-44 Troubleshooting
13. Press the black OFF (0) button on the Operator’s Console and switch the Main Circuit Breaker to the
OFF (0) position.
14. Disconnect the Servo AC Power Cord (P/N 56-0304-00) from Power Manager outlet AC3.
15. Switch the Main Circuit Breaker to the
ON (I) position and press the green ON (I) button on the
Operator’s Console.
16. Measure the VAC coming from the Power Manager outlet AC3.
17. Is the reading between 208 and 240 VAC?
Power Manager (P/N 62-1620-01) has failed.
See
Parts Replacement section.
Go to Step 18
18. Press the black OFF (0) button on the Operator’s Console and switch the Main Circuit Breaker to the
OFF (0) position.
19. Reconnect the Servo AC Power Cord (P/N 56-0304-00) to the Power Manager.
20. Disconnect the Servo AC Power Cord (P/N 56-0304-00) from the Servo Transformer AC POWER
inlet.
21. Switch the Main Circuit Breaker to the
ON (I) position, and press the green ON (I) button on the
Operator’s Console.
22. Measure VAC coming from the Servo AC Power Cord.
23. Is the reading between 208 and 240 VAC?
Power Cord (P/N 56-0304-00) has failed. See Parts
Replacement
section.
Servo Transformer (P/N 04-0045-00) has failed. See
Parts
Replacement
section.
No
Yes
No
Yes