Installation Manual
Troubleshooting 8-33
Interlock Power Verification
1. Verify the Main Circuit Breaker on the Power Manager is in the
ON (I) position.
2. Is the Power Manager Fan functioning?
Go to 8.1.2, Main Power Fault Isolation
Procedure
Go to Step 3
3. Is the green Computer power LED illuminated?
Go to Step 4
Go to “System/Servo Power Verification” in 8.1.1, X and Y Motion Fault
Isolation Procedure
4. Verify the Computer Power Switch is in the ON (I) position.
5. Does the green Computer power LED illuminate?
Go to 8.1.2, Main Power Fault
Isolation Procedure
Go to Step 6
6. Locate the power LEDs on the XY Servo Interface PWA.
7. Are the green 5V, A+15V, and A+5V LEDs illuminated?
Go to 8.1.2, Main Power Fault
Isolation Procedure
Go to Step 8
8. Press the green ON (I) button on the Operator’s Console.
9. Does the green
ON (I) button on the Operator’s Console illuminate?
Go to 8.1.3, System Power Fault
Isolation Procedure
Go to Step 10
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes