Installation Manual
Troubleshooting 8-29
4. Is there continuity between the pins specified in Table 8-15?
The OFF (0) button (P/N 40-2485) has failed.
See
Parts Replacement section.
Cable (P/N 06-4515-00) has failed. See
Parts Replacement section.
XY Servo Interface Power Verification
1. Locate the power LEDs on the Main Interface PWA.
2. Is the +24V LED illuminated?
Go to Step 3
Go to Step 17
3. Press the black OFF (0) button on the Operator’s Console.
4. Switch the Main Circuit Breaker to the
OFF (0) position.
5. Disconnect the +24V Power Cable (P/N 06-4510-00) from the Main Interface Board +24V POWER
IN connector.
6. Switch the Main Circuit Breaker to the
ON (I) position.
7. Press the green
ON (I) button on the Operator’s Console.
8. Measure VDC between Pin 1 and Pin 2 on the +24V Power Cable (P/N 06-4510-00).
9. Is the reading greater than 23 VDC?
Go to Step 10
Go to Step 17
10. Press the black OFF (0) button on the Operator’s Console.
11. Switch the Main Circuit Breaker to the
OFF (0) position.
12. Disconnect the +24V Power Cable (P/N 06-4510-00) from the Main Power Manager +24V DC
POWER OUT connector.
13. Switch the Main Circuit Breaker to the
ON (I) position.
14. Press the green
ON (I) button on the Operator’s Console.
No
Yes
No
Yes
No
Yes