Installation Manual
8-28 Troubleshooting
Vent Switch Faker Verification
1. Switch the Main Circuit Breaker to the
OFF (0) position.
2. Reconnect the Cable (P/N 06-4515-00) to the Power Control outlet on the Power Manager.
3. Verify the Vent Switch Faker (P/N 194034) is connected to J9.
4. Is the Vent Switch Faker connected?
Install Vent Switch Faker (P/N 19034) and then go
to Step 5.
Go to Step 5
5. Verify the continuity of the Vent Switch Faker pins is as specified in Table 8-14.
Table 8-14 Vent Switch Faker Pin Connections
Pin Connections
Pin 1 to Pin 2
Pin 3 to Pin 4
6. Is there continuity between the pins specified in Table 8-14?
Vent Switch Faker (P/N 19034) has failed.
See
Parts Replacement section.
Power Manager (P/N 62-1620-01) has failed. See
Parts
Replacement
section.
Operator’s Console OFF (0) Button Verification
1. Reconnect the Cable (P/N 06-4515-00) to the Power Control outlet on the Power Manager.
2. Verify the
OFF (0) button on the Operator’s Console is assembled and connected to the
Cable (P/N 06-4515-00).
3. Verify continuity of the
OFF (0) button pins specified in Table 8-15.
Table 8-15 Off Button Cable Connections
Off Button Cable
Connector
Wire Color
Pin 1 to Pin 2 Black to White
Pin 2 to Pin 4 Red to Green
No
Yes
No
Yes