Installation Manual

8-22 Troubleshooting
11. Press the green ON (I) button on the Operator’s Console.
12. Does the green
ON (I) button on the Operator’s Console stay illuminated?
Go to Step 13
Stop here. Dispensing system being in EMO state is root cause of
power fault.
13. Verify the proper cables are connected to the Power Manager as specified in Table 8-5.
Table 8-5 Cable Connections to the Power Manager
Power Manager
Connection
Cable
Power Control (J5) P/N 06-4515-00
Rear EMO (J8) P/N 06-4511-00
Vent Switch Faker (J9) Connector with Pin 1 to Pin 2 and Pin 3 to Pin
4 shorted. Vent Switch Faker P/N 194034.
14. Are the cables connected to the Power Manager as specified in Table 8-5?
Go to Step 15
Go to Step 19
15. Switch the Main Circuit Breaker to the OFF (0) position.
16. Order correct replacement Cables as appropriate. Connect the new Cables to Power Manager as
specified in Table 8-5.
17. Power-up the Power Manager by switching the Main Circuit Breaker to the
ON (I) position.
18. Press the green
ON (I) button on the Operator’s Console.
19. Does the green
ON (I) button on Operator’s Console illuminate?
Go to Step 20
Stop here. Cables are root cause of system power fault.
20. Switch the Main Circuit Breaker to the OFF (0) position.
21. Verify the green
ON (I) button is assembled and connected to Cable P/N 06-4515-00.
No
Yes
No
Yes
No
Yes