Installation Manual

Troubleshooting 8-21
System Power Verification
1. Press the green
ON (I) button on the Operator’s Console.
2. Does the green
ON (I) button stay illuminated?
Go to Step 7
Go to Step 3
3. Locate the power LEDs on the XY Servo Interface PWA.
4. Are the green +24V_A&B_ISO and +24V LEDs illuminated?
Go to XY Servo Interface Power Verification in
this subsection.
Go to Step 5
5. Locate the Dispense Head Controller status LEDs on the left side of the Dispensing Head.
6. Are the top three green D16, D17, and D18 LEDs illuminated?
Go to Dispense Head Controller Power
Verification in this subsection.
Stop Here. No system power fault. Verify fault. Contact Asymtek Technical
Support if fault reoccurs.
7. Locate the power LEDs on the XY Servo Interface PWA.
8. Are the green 5V, A+15V, and A+5V LEDs illuminated?
Go to 8.1.2, Main Power Fault Isolation
Procedure
Go to Step 9
9. Is the front or rear EMO Button depressed?
Go to Step 13
Go to Step 10
10. Rotate front and rear EMO Buttons counterclockwise until released.
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes