Installation Manual
1-2 Introduction
Facility Requirements
Before installing the Axiom X-1000 Series Dispensing System, you must take into account the facility
requirements listed in Table 1-1. Meeting the requirements specified will ensure reliable operation and
safety of the dispensing system.
WARNING! CAUTION!
Make sure that your facility meets the requirements below. Failure to meet these
requirements could result in serious injury to personnel and damage to the
dispensing system.
Table 1-1 Facility Requirements
Characteristic Specification
System Footprint 1443 mm X 1100 mm (56.8 in. x 43.3 in.) See Figure 1-1 and
Figure 1-2.
Power (Main) 180–260 VAC single phase, 30 A, 50/60 Hz, connected through
a 3 meter cord with NEMA L6-30 male locking plug /female IEC
60309 connector
Main Breaker Current
Interrupting Capacity
30 amperes
Main Breaker AIC Rating 10 kA
Air Supply Pressure: 621 kPa (6.1 atm, 90 psi)
Flowrate: 28–198.2 liters/min. (1–7 SCFM) depending on
configuration
Pneumatic Fitting Required
Quick Disconnect: included with shipping kit. ¼-in. male NPT
required for connection to QD.
Noise <70 dBA
System Weight 435 kg (960 lbs)
Environmental
Storage/Operation Temperature: 5 to 55 C (41 to 131 F)
Relative Humidity: 5 to 90% (below 40 C)
Standards Compliance SMEMA, CE, SEMI-S2, SEMI-S8
Note: If you have any questions about facility requirements, please contact Asymtek
Technical Support or your authorized distributor.