Installation Manual
Theory of Operation 7-11
Pneumatics Distribution
Pneumatic distribution can vary depending upon system configuration. Figure 7-2 diagrams the
pneumatic distribution on a typical Axiom X-1000 Series Dispensing System.
? NOTE Refer to Figure 5-5 in the Power-up and Testing section and the pneumatics block
diagram in the Appendix A, if necessary.
Figure 7-2 Flow Diagram - Pneumatic Distribution
Main Air Regulator
Assembly
Main Air
Solenoid
Low Air
Sensor
Dual Action
Valve
Solenoid Valve
Manifold
Fluid Pressure
V1 and V2
Valve Pressure
Tooling
Pressure
Impingement
Flowmeters
Lift Tables or
Clamp Bars
Vacuum
Generators
and Purge Cup
Stop Pins