Installation Manual

6-26 Calibration and Adjustment
To adjust the Encoder Scanner to Encoder Scale gap:
1. If it is not already open, open the dispensing system Hatch.
WARNING! Make sure the yellow beacon light is displayed and all system motion has stopped
before reaching into the dispensing area. If the Heaters are still hot, use extreme
caution when performing this operation.
2. Loosen the two 3-mm hex screws on the top of the Scanner.
3. Insert the 0.9-mm gapping tool into the space between the Scanner and the Scale.
4. Move the Scanner toward or away from the Scale until the gapping tool fits snugly between
them.
> If you cannot get a good fit, contact Asymtek Technical Support.
5. Hold the Scanner in place and retighten.
6. Close the dispensing system Hatch.