Installation Manual
6-18 Calibration and Adjustment
11. Dial the thumbwheel one click towards the minus position.
> GOOD should display for two seconds, indicating the ON-OFF threshold is identifiable.
If
HARD is displayed, then the sensor may not be able to tell the difference between ON
and OFF. The Board Sensor lens will require realignment before proceeding.
`
Item Description Item Description
1 Rear Conveyor Rail 6 Thumbwheel
2 Board Sensor 7 Fiber Optic Amplifier
3 LED Display 8 Dispensing Area Front Cover
4 Output Switch 9 Dispensing Calibration Module
5 Mode Selection Switch
Figure 6-8 Sensor Sensitivity Adjustment