5-46 Power-up and Testing
6. View the image in the video display.
> If the image is still focused, the height of the DCM does not need to be adjusted.
> If the image is not focused, the height of the DCM must be adjusted to be in the same
plane as the workpiece. Refer to “Dispensing Calibration Module Leveling and Height
Adjustment” in the Calibration and Adjustment section of this manual.
7. Look at the Circular Level that is in the well on the top of the DCM. See Figure 5-13.
> If the bubble is centered, the DCM is level.
> If the bubble is not centered, refer to “Dispensing Calibration Module Leveling and
Height Adjustment” in the Calibration and Adjustment section of this manual.
8. When the DCM has been leveled and height adjusted, click on
Done to exit the Reticle
Settings dialog box and then click on
OK in the Setup Vision dialog box to return to the Main
Window.