Power-up and Testing 5-45
Figure 5-23 Scale Setup Dialog Box
Dispensing Calibration Module
Perform the following steps to verify the Dispensing Calibration Module (DCM) is at the proper height
and is level.
? NOTE This procedure assumes that the Vision System has been checked and calibrated and that
the Scale is level.
1. Open the dispensing system Hatch, place a production sample workpiece in the dispense
station of the Conveyor, and close the Hatch.
2. In the FmNT Main Window, click on
Configuration and then select Setup Vision.
3. In the Vision dialog box, click on the
Setup Reticles button. See Figure 5-21.
4. Focus the Camera on a fiducial of the sample workpiece.
5. Use the target box or X-and Y-axis position controls in the Reticle Settings dialog box to
move the Camera over a corner of the white ceramic tile near the Needle Sensor.