Owner manual

4-18 Operation
Table 4-6 Pressurized Air Controls
Item Name Description
1 Valve Air Pressure
Regulator and
Gauge Set
Controls the air pressure that actuates some dispensing valves
(DJ-9000, DP-3000) during dispensing. For details on how air is
used for dispensing valve operation, refer to the applicable
dispensing valve manual.
In dispensing systems with a Dual-Action Dispensing Head, the
Valve Air Pressure Regulator and Gauge set can supply both
dispensing valves with air pressure.
Consult the applicable dispensing valve manual for the
recommended pressure setting.
2 Fluid Air Pressure
Regulator and Digital
Gauge Set
Controls the air pressure going to the receiver head of the fluid
syringe or reservoir to maintain a constant flow of fluid to the
dispensing valve.
The air pressure supplied to the syringe or reservoir depends on the
type of fluid and the dispensing valve being used. Refer to the
applicable dispensing valve manual for recommended pressure
settings.
There are two independent Fluid Air Pressure Regulator and Gauge
sets to support a Dual-Action Dispensing Head option.
3 Tooling Vacuum Digital
Gauges (optional)
Provide vacuum pressure readings for contact heaters in up to three
conveyor stations.
4 Impingement
Flowmeters
Control airflow going to impingement heaters installed at up to three
conveyor stations. Refer to Table 4-5 for the recommended flowrate.
5 Cooler Air Pressure
Regulator and Digital
Gauge Set
Controls air pressure for the thermal control assembly on a DJ-9000
Series dispensing valve. Refer to Table 4-5 for the recommended
pressure.
6 Tooling Air Pressure
Regulator and Gauge
Set
Controls air pressure for stop pins and lift tables/clamp bars. Refer to
Table 4-5 for the recommended pressure.
7 Impingement Air
Shutoff Valve (X-1020)
Allows the air supply to the flowmeters to be turned off when
impingement heater tooling is inactive.
8 Lift Table Air
Shutoff Valve (X-1010)
Allows the air supply to lift tables to be turned off when they are
inactive.