Owner manual
Operation 4-15
4.5.3 Pneumatic Controls
The Axiom X-1000 Dispensing System has pneumatic regulators, flowmeters, and associated gauges that
control the following:
• Main Air (refer to 4.5.3.1 Main Air Regulator)
• Fluid Air
• Dispensing Valve Air
• Cooling Air (DJ-9000) (refer to 4.5.3.2 Pneumatic Controls in the Lower Front Cabinet)
• Tooling Air
• Impingement
Recommended pressure settings are provided in Table 4-5. Refer to 4.5.3.3 for adjustment procedures.
Table 4-5 Recommended Pressure Settings and Flowrates
Device
Recommended
Pressure/Flowrate
Comments
Main Air Pressure Regulator 620.5 kPa (90 psi)
Facility pressure is 586 to 620 kPa
(85 to 90 psi).
Fluid Air Pressure Regulator 206 to 275 kPa (30 to 40 psi)
Depends on fluid being dispensed and
dispensing valve being used. Refer to
the applicable dispensing valve manual.
Tooling Air Pressure
Regulator
413.6 kPa (60 psi) --
Valve Air Pressure Regulator
482.6 kPa (70 psi),
approximate
Depends on the dispensing valve used.
Refer to the applicable dispensing valve
manual.
Cooler Air Pressure (X-1020) 413.6 kPa (60 psi)
Used with the DJ-9000 Series
dispensing valve only.
Impingement Flowmeters
113 L/min. (4.0 SCFM)
maximum
Depends on the design of the
Impingement Heater.