4-6 Operation
4.4 System Shutdown
4.4.1 Emergency Shutdown
WARNING! CAUTION!
In an emergency, failure to completely shut down power to the dispensing
system with the EMO can cause serious injury to the user and damage to the
dispensing system.
During an emergency or malfunction, press the red EMO button on the Control Panel or on the back of
the dispensing system (see Figure 2-3 for locations). Pressing EMO button cuts the power to all
dispensing system components except the computer and monitor and vents all pneumatic pressure.
For more information on emergency shutdown situations and instructions on restoring system power after
an emergency shutdown, refer to the Safety section.
4.4.2 Production Shutdown (End of Shift)
Depending on your company’s requirements, your X-1000 Series Dispensing System may be left ON or
OFF at the end of a shift. However, we recommend that you incorporate the following procedure into
your production shutdown routine: .
1. Wait for the dispensing program to complete.
2. Purge the dispensing valve as specified in the applicable dispensing valve manual.
3. Save any changes to dispensing programs and then exit Fluidmove.
4. Press the black OFF button on the operator’s console.
5. Verify that all dispensing system motion has stopped.
WARNING! The Needle Heater and Tooling Plates retain heat for a time after the system has
been shut down. Use extreme caution around these components to prevent burn
injuries.
6. Remove all workpieces from the dispensing chamber.
7. Remove the fluid syringe from the dispensing head as specified in the applicable dispensing
valve manual.
8. Clean the dispensing valve as specified in the applicable dispensing valve manual.