Owner manual
2-10 Safety
2.7 Earthquake Precautions
2.7.1 Personnel
To prevent injury during an earthquake, all personnel should follow facility earthquake safety guidelines.
2.7.2 System Safe Mode
Your X-1000 Dispensing System is designed to automatically go into a safe mode if electrical power is
lost due to an earthquake. All hazardous electrical and pneumatic energy is bled out of the system.
2.7.3 Movement
During an earthquake, your dispensing system must be secured to prevent movement that could cause
injury to personnel and damage to the dispensing system and facility. Each dispensing system Leveler
(foot) should be anchored to the floor with two bolts. See Figure 2-4.
The anchor joint (the point between
each anchor bolt and the floor) must be able to withstand at least 220 lbs (100 kg) of pullout force.
Item Description
1 Lock Nut (shown in locked position)
2 Leveler (foot)
3 Floor
4 Anchor Bolt
5 Dispensing System
Figure 2-4 Earthquake Protection, Side View
1
2
3
5
4