Owner manual

2-8 Safety
2.5.1 Emergency Shutdown Situations
As a minimum, activate the EMO in the following situations:
WARNING! CAUTION!
In an emergency, failure to completely shut down power to the dispensing
system with the EMO can cause serious injury to the user and damage to the
dispensing system.
If anyone is in immediate danger of being injured by moving parts, hazardous materials, or
electrical shock.
If valuable dispensing system components or the workpieces are in danger of being damaged.
This can include:
- Physical damage to the dispensing valve or workpiece by unexpected dispensing
head movement.
- Thermal damage to the workpiece due to overheating of heater tooling.
- Electrical damage to the dispensing system.
2.5.2 Emergency Shutdown Recovery
To recover after an emergency shutdown:
WARNING! CAUTION!
Do not restart the dispensing operation until the condition causing the emergency
shutdown has been alleviated. Failure to comply could cause serious injury to the
user and serious damage to the dispensing system.
NOTE If the main circuit breaker has been tripped, you will need to switch it back ON (I) and
execute standard startup procedure. Refer to Section 4 - Operation.
1. Open the hatch and clear the conveyor of all workpieces.
2. Locate and remedy the cause of the emergency shutdown. If necessary, refer to
Section 5 - Troubleshooting or the Troubleshooting section in the Axiom X-1000 Series
Installation and Service Manual.
3. Close the hatch.
4. Turn the red EMO knob counterclockwise until it pops back into position.
5. Press
ON (l) on the operator’s console.
6. Fluidmove will display a prompt asking if you want to reinitialize or abort the program.
7. Restart the dispensing program as specified in Section 4 - Operation.