Owner manual
7-2 Specifications
7.3 Specifications
Table 7-1 Facility Requirements
Characteristic Specification
System Footprint 1443 mm X 1100 mm (56.8 in. x 43.3 in.) See Figure 7-1 and
Figure 7-2.
Power (Main) 180–260 VAC single phase, 30 A, 50/60 Hz, connected through
a 3 meter cord with NEMA L6-30 male locking plug /female IEC
60309 connector
Main Breaker Current
Interrupting Capacity
30 amperes
Main Breaker AIC Rating 10 kA
Air Supply Pressure: 621 kPa (6.1 atm, 90 psi)
Flowrate: 28–198.2 liters/min. (1–7 SCFM) depending on
configuration
Pneumatic Fitting Required Quick Disconnect: included with shipping kit. ¼-in. male NPT
required for connection to QD.
Noise <70 dBA
System Weight 435 kg (960 lbs)
Environmental
Storage/Operation Temperature: 5 to 55 C (41 to 131 F)
Relative Humidity: 5 to 90% (below 40 C)
Standards Compliance SMEMA, CE, SEMI-S2, SEMI-S8
Note: If you have any questions about facility requirements, please contact Asymtek Technical Support or your
authorized distributor.
Table 7-2 System Performance Metrics
Characteristic Specification
MTBF >100 hours
MTBA >3 hours
MTTR <2 hours
MTTA <6 minutes
Availability >93%
Note: Performance metrics are from SEMI E10. These numbers are intended to represent minimum
expected performance and are based upon a single valve application with a 30cc syringe in a typical
underfill application. Actual numbers will be dependent upon the end application and other factors
such as fluid syringe size, dispensed volume per part, management of Fluidmove software, and
application of SEMI E10 definitions to the particular activity.