Owner manual
Maintenance 6-3
Table 6-1 Recommended Maintenance
Maintenance Task
Recommended
Frequency
Instructions
Clean purge station boot. Daily 1. Remove the purge station cover. Do not attempt to
remove the boot from the cover or the boot may be
damaged.
2. Carefully clean the boot and purge station cover with
a soft cloth and the cleaning agent recommended by
the fluid manufacturer (see the MSDS).
3. Replace purge station cover.
Replace purge station cup. Daily
Refer to 6.6 Replacing Purge and Weigh Station Cups.
Replace weigh station cup and
banjo wiper (if applicable to your
system).
Daily
Inspect conveyor belt o-rings. Daily Visually inspect the o-rings for cracks or splits. Notify a
service technician immediately if you notice any damage.
Do not use the system if the o-rings are damaged.
Inspect Height Sensor Probe. Daily Visually inspect the probe for fluid buildup and damage.
• Clean fluid on the probe using a soft cloth with
cleaning agent recommended by the fluid
manufacturer (see the MSDS).
• To replace damaged probes, refer to 6.8 Replacing
a Height Sensor Probe.
Drain water trap. Weekly or
When Full
Refer to 6.7 Draining the Water Trap.
Clean hatch window and Monitor
screen.
Weekly Use ammonia-based window cleaner or isopropyl alcohol
and a clean, soft cloth.
Replace purge station boot. Every 2 weeks Refer to 6.5 Replacing Purge Boots.
Clean conveyor belts and rails. Every 2 weeks 1. Clear the conveyor of all boards or carriers.
2. Open the hatch and manually move the Dispensing
Head to the back of the dispensing area.
3. Using isopropyl alcohol and a soft cloth, wipe the
length of each conveyor belt.
4. Using MSDS-recommended cleaning agent and a
soft cloth, clean any wet or dry fluid that may have
spilled on the conveyor rails.
5. Close the hatch.
Clean dispensing system chassis. Every 2 weeks Use isopropyl alcohol and a clean, soft cloth to wipe
down the top, sides and front of the dispensing system.
Make sure that you remove all residual fluid and dirt.
Clean fluid from miscellaneous
surfaces (such as the DCM).
As needed
• For damp spills, wipe with a clean, dry, soft cloth.
• For dried spills, clean with the manufacturer MSDS
recommended cleaning agent and a clean, soft
cloth.
Clean dispensing valve. As recommended
in the applicable
dispensing valve
manual.
For cleaning instructions and recommended cleaning
schedule, refer to the maintenance section of the
applicable dispensing valve manual.