Owner manual

Maintenance 6-1
6 Maintenance
6.1 Overview
This section describes the recommended periodic maintenance procedures that a trained operator can
perform to increase system life and ensure high quality dispensing performance. This section covers the
following:
Maintenance Schedule
Purge Boot Replacement
Purge Station and Weigh Station Cup Replacement
Draining the Water Trap
Height Sensor Probe Replacement
6.2 Safety First
Before performing maintenance procedures, please familiarize yourself with the important information
provided in Section 2 - Safety.
6.2.1 Machine Status
Unless otherwise specified, the dispensing system may be left powered ON while performing the
following maintenance procedures. Lifting the hatch to access the dispensing area will automatically
activate the Safety Interlock putting the system in a low-power state.
CAUTION! Avoid opening the hatch while a dispensing program is running or the workpiece
may be not be completely dispensed.
6.2.2 Hazardous Materials
Some maintenance procedures involve the use of hazardous materials. Always follow all applicable
national and local statutes and regulations, facility safety practice, and the material manufacturer's
Material Safety Data Sheet (MSDS) recommendations including:
Personal protective equipment (such as rubber gloves, safety glasses, thermal gloves)
Disposal of contaminated items (such as purge boots, fluid syringes, cleaning cloths)
Disposal of hazardous materials (such as cleaning agents, dispensing fluid, lubricants)
Treatment of injury to personnel
Material flammability
WARNING! Isopropyl alcohol is flammable. Do not use near heat or flame.