4-26 Operation
4.6.2 Thermal Control Assembly Operation
CAUTION! The operator can turn the Thermal Control Assembly on and off and monitor its
function. However, only a trained service technician should set heater
parameters.
NOTE Contact your applications engineer or Asymtek Technical Support for information about
setting heater/cooler parameters for your particular application.
Operate the heater/cooler as follows:
WARNING! The heater may be hot. Avoid touching heater surfaces or burn injury may occur.
1. In the Fluidmove Main Window, click on Run a Program .
2. In the Production Window (Figure 4-13), click on
Setup and in the list box select Setup
Heater 1
.
Figure 4-13 Fluidmove Production Window
3. If the dispensing valve was just switched to the DJ-9000, load the heater/cooler file as
follows:
In the Heater Control Window (Figure 4-14), click on the
Download button.
Double-click on file
C:\FMNT\heater1\DJ-9K Nozzle Cooler.