Quick Operations Owner's manual

1-2 Introduction
System Configuration
Your dispensing system was configured at the Asymtek factory for your specific application prior to shipping.
Table 1-1 compares the features and capabilities of the X-1000 Series Dispensing System models covered
by this manual.
Table 1-1 System Configurations: Axiom X-1000 Series
Model
Features
X-1010 X-1020
Applications Surface Mount Flip Chip Underfill, Dam & Fill, Cavity Fill
Recommended
Valve Series
DJ-2000, DJ-9000
DV-7000, DV-8000
*Dual Valve Combinations (option)
DJ-2000, DJ-9000
DP-3000
DV-01 through DV-05, DV-07 through DV-09,
DV-7000, DV-8000,
*Dual Valve Combinations (option)
Needle Heater
(For DV & DP
Series Valves)
Option - Resistive Temperature Detector (RTD)
type [Ambient to 120 °C (50 to 70 °F) typical]
Standard - RTD type [Ambient to 120 °C (50 to 70
°F) typical]
Weigh Station None Standard
Conveyor
Control by Conveyor/Heater Controller
SMEMA Compliant
O-ring Drive
Motorized Rail Spacing
Board Edge Clamp
2 Stations
Under-the-Rail Board Sensors at All
Stations
Over-the-Rail Stop Pins
Control by Conveyor/Heater Controller
SMEMA Compliant
O-ring Drive
Motorized Rail Spacing
3-Lift Tables Standard for Tooling
Engagement
3 Stations
Fiber-optic Over-the-Rail Board Sensors at
All Stations
Over-the-Rail Stop Pins
CAD Import Standard Option
Software Fluidmove for Windows NT (FmNT)
SECS-GEM
Interface
Option
Substrate
Heating
Option (Contact or Impingement Heaters)
Needle Sensor Standard
Height Sensor Standard: Slim Line Retractable Tactile (option)
Option: Laser
Purge Station Standard
Vision System Type: Automatic Pattern Recognition
Camera: Miniature, High Resolution with 12.7-mm (0.5-inch) Image Size
Lighting: Red & Blue Variable Diffuse On-Axis LED Through Lens
Computer
System
CPU: Celeron PC with 88.9-mm (3.5-in.) floppy and CD-RW drives and Ethernet network port
Monitor: 307-mm (12.1-in.) color LCD flat-panel display,
Keyboard: ASCII
Dual-Action
Dispensing
Head
Option
Low Fluid
Sensor
Option
Free-Standing
Loader
Option (upstream and downstream)