Quick Operations Owner's manual
5-6 Maintenance
To replace the Purge and Weigh Station cups:
WARNING!
Follow all local regulations, the material manufacturer MSDS, and facility practices
concerning personal protective equipment and disposal of hazardous materials.
" NOTE The Valve Offsets routine does not need to be performed after replacing the Purge Station
and Weigh Station cups.
1. When the dispensing system is idle, open the dispensing system Hatch.
2. Remove the Purge and Weigh Station covers. See Figure 5-2.
3. Remove and discard the plastic cup inside the Purge Station and inspect the interior surfaces for
spilled fluid.
! If the interior of the Purge Station has spilled fluid, clean with the fluid manufacturer MSDS
recommended cleaning agent and a soft cloth.
4. Remove and discard the cup and banjo wiper inside the Weigh Station and inspect the interior
surfaces for spilled fluid.
! If the interior of the Weigh Station has spilled fluid, call a service technician.
CAUTION!
Avoid putting downward pressure on the Scale or damage to the sensitive weighing
mechanism will occur.
5. Place a new plastic cup inside of each station.
6. Place a new banjo wiper into the Weigh Station cup such that the wide sides of the wiper are
perpendicular to the Conveyor Rail.
7. Clean the covers using isopropyl alcohol and a soft cloth.
WARNING!
Isopropyl alcohol is flammable. Do not use near heat or flame.
8. Replace the Purge Station and Weigh Station Covers.
9. Close the Hatch.
! If a dispensing program was running, it will restart where it left off.