Quick Operations Owner's manual
Maintenance 5-3
Table 5-1 Recommended Maintenance (continued)
Maintenance Task
Recommended
Frequency
Instructions
Inspect Height Sensor Probe. Daily
Visually inspect the probe for fluid buildup
and damage.
• Clean fluid on the probe using a soft cloth with
cleaning agent recommended by the fluid
manufacturer (see the MSDS).
• To replace damaged probes, refer to
“Replacing a Height Sensor Probe” in
this section.
Drain Water Trap.
Weekly or
When Full
Refer to “Draining the Water Trap” in this section.
Clean Hatch window and
Monitor screen.
Weekly
Use ammonia-based window cleaner or isopropyl
alcohol and a clean, soft cloth.
Replace Purge Station boot. Every 2 weeks See “Replacing Consumables” in this section.
Clean Conveyor belts
and rails.
Every 2 weeks
1. Clear the Conveyor of all boards or carriers.
2. Open the Hatch and manually move the
Dispensing Head to the back of the
dispensing area.
3. Using isopropyl alcohol and a soft cloth, wipe
the length of each Conveyor belt.
4. Using MSDS-recommended cleaning agent
and a soft cloth, clean any wet or dry fluid that
may have spilled on the Conveyor rails.
5. Close the Hatch.
Clean dispensing system
chassis.
Every 2 weeks
Use isopropyl alcohol and a clean, soft cloth to
wipe down the top, sides and front of the
dispensing system. Make sure that you remove all
residual fluid and dirt.
Clean fluid from miscellaneous
surfaces (such as the DCM).
As needed
• For damp spills, wipe with a clean, dry,
soft cloth.
• For dried spills, clean with the manufacturer
MSDS recommended cleaning agent and a
clean, soft cloth.
Clean Dispensing Valve.
A
s recommended
in the applicable
Dispensing Valve
manual.
For cleaning instructions and recommended
cleaning schedule, refer to the maintenance
section of the applicable Dispensing Valve
Installation and Operations manual.
" NOTE Other recommended maintenance procedures that should be performed only by a
trained service technician are outlined in the Axiom X-1000 Installation and
Service Manual.