Quick Operations Owner's manual
4-8 Operation
Control Buttons and Switches
The location of the primary control buttons and switches that are accessible to the operator are located as
shown in Figure 4-5. The function of these buttons and switches is described in Table 4-4.
Table 4-4 Control Buttons and Switches
Button/Switch Appearance Function
EMO Buttons
The large, red EMO button is located on the right side of
the Operator’s Console and on the rear right side of the
dispensing system. Pressing this button causes the
Power Manager to power down potentially hazardous
electrical and pneumatic energy sources in the system.
The Computer and the monitor remain operational.
WARNING!
Although the system has been powered down, Heater
Tooling and Needle Heaters still present a thermal hazard
until they cool.
System ON/OFF
Buttons
ON/I OFF/0
The System ON and OFF buttons are located on the left
side of the Operator’s Console. They control power to
major system components. The left (green) button is the
system ON button. The right (black) button is the System
OFF button.
Main Power Circuit
Breaker
I
O
The Main Power Circuit Breaker, on the lower left rear
panel of the dispensing system, control all power being
supplied to the dispensing system. The I position is ON,
and the 0 position is OFF.